9.680 Terrasat-IBUC-SNMP

This page describes the device driver and the device window for the Terrasat Ku-Band and C-Band L-Band Blockupconverter (IBUC) and supports the built-in 1+1 TX redundancy configuration.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameter which must be set to make the software talk to the transceiver.

parameter description
address The device driver uses the terminal protocol to talk with the transceiver, hence there is no device addressing. Leave this field empty.
externalLED This enables or disables the LED on the chassis.
outputHighLimit Output high power level trehshold
outputLowLimit Output low power level threshold
inputHighLimit Input high power level threshold
inputLowLimit Input low power level threshold
password This is the passwort which is used for login
txPowerupDelay Sets the delay for tx on at power up
txPowerupState If set to 'OFF', the IBUC starts with RF OFF when it is powered up. The 'LAST STATE' setting lets the transceiver return to the state when it was switched off

Ethernet connection

If you want to use the TCP/IP M&C interface you have to configure the IP address of the IBUC first. Please refer to the Terrasat IBUC User Manual. If you want to use the telnet M&C interface or the serial M&C interface please use the driver Terrasat-IBUC

SNMP configuration

The following commands (via telnet or serial interface) configure SNMP operation on the IBUC:

command default description
CIT 0 This command enables or disables the SNMP trap capabilities of the IBUC. CIT=1 enables traps. SNMP must be enabled to generate traps(CIS=1). CIT=0 disables traps. CIT? returns the current setting of traps.
CIS 0 This command enables or disables the SNMP functionality of the IBUC. CIS=1 enables SNMPV1. CIS=0 disables SNMPV1. CIS? returns the current setting of SNMP functionality.
CIC public,private,trap sets the SNMP passwords for the IBUC. CIC=<public>,<private>,<trap> where public is the public password, private is the private password, and trap is the trap password. All three passwords are required when issuing this command. Each password cannot exceed 16 characters. Passwords may not be read for security purposes.

1+1 Redundancy / Protection switching

If you have a 1+1 IBUC TX redundancy you have to configure both IBUC's first via web browser interface. Then you can configure two devices (e.g. BUC-A and BUC-B) within the sat-nms M&C system. The active unit (that one which is not switched to dummy load) is automatically the master unit. You can only send commands to the master. The slave unit will not accept any commands.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.outputHighLimit FLOAT SETUP DoubleRange (10.00 .. 60.00)
config.outputLowLimit FLOAT SETUP DoubleRange (10.00 .. 60.00)
config.inputHighLimit FLOAT SETUP DoubleRange (-60.00 .. -15.00)
config.inputLowLimit FLOAT SETUP DoubleRange (-60.00 .. -15.00)
config.txPowerupDelay INTEGER SETUP IntegerRange (0 .. 500)
config.txPowerupState CHOICE SETUP EnumRange (LAST STATE OFF)
config.highTempShutdown CHOICE SETUP EnumRange (ON OFF)
config.txBand CHOICE SETUP EnumRange (SINGLE BAND COMMERCIAL-RF-BAND-1 COMMERCIAL-RF-BAND-2 COMMERCIAL-RF-BAND-3 MILITARY-RF-BAND-1 MILITARY-RF-BAND-2)
config.ifBand CHOICE SETUP EnumRange (IF-BAND-1 IF-BAND-2)
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.firmware TEXT R/O StringRange R/O
info.powerClass CHOICE R/O EnumRange R/O (2 Watt 4 Watt 5 Watt 8 Watt 10 Watt 16 Watt 20 Watt 25 Watt 40 Watt 60 Watt 30 Watt 80 Watt 100 Watt 12 Watt 50 Watt 125 Watt 150 Watt 200 Watt 175 Watt 400 Watt 15 Watt)
info.ipAddress TEXT R/O StringRange R/O
info.otherAddress TEXT R/O StringRange R/O
info.loFrequency CHOICE R/O EnumRange R/O (Standard C-Band Instat C-Band Extended Ku-Band Standard Ku-Band X-Band 7 Full Ku-Band Extended C-Band Full C-Band Low Ku-Band Palapa C-Band High Ku-Band DBS-Band 1 DBS-Band 2 Ka-Band 1 Ka-Band 2 Ku-Band 4 C-Band 6 Ka-Band 3 Ka-Band 4)
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
rx.measuredLevel FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.burstCount INTEGER IntegerRange (1 .. 16)
tx.burstThreshold FLOAT DoubleRange (0.00 .. 60.00)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 16.0)
tx.attn FLOAT DoubleRange (0.0 .. 16.0)
tx.frequency INTEGER IntegerRange (0 .. 0)
tx.controlMode CHOICE EnumRange (Open loop ALC AGC)
tx.gainTarget FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.levelTarget FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.gainControl FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
tx.powerReadMode CHOICE EnumRange (CSM (cont.) Burst)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.000 .. 0.000)
meas.vdc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.idc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temperature INTEGER R/O IntegerRange R/O (0 .. 0)
meas.pldroVoltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
protection CHOICE EnumRange DIS (MANUAL AUTO)
autoClone CHOICE EnumRange DIS (OFF ON)
redundancyMode CHOICE EnumRange DIS (reverting non-reverting)
onSwitch CHOICE EnumRange DIS (attached as A attached as B)
location CHOICE EnumRange DIS (A B)
position CHOICE EnumRange DIS (A B)
txSwitch CHOICE EnumRange DIS (ANTENNA LOAD)
reset TEXT NOPRESET StringRange
switchedReset TEXT NOPRESET StringRange
internal.redundancy INTEGER IntegerRange (0 .. 0)
internal.snmp TEXT R/O StringRange R/O
internal.version TEXT R/O StringRange R/O
internal.model TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (DRO lock alarm)
faults.02 ALARM R/O AlarmFlagRange R/O (AGC/ALC not settled)
faults.03 ALARM R/O AlarmFlagRange R/O (AGC/ALC target range)
faults.04 ALARM R/O AlarmFlagRange R/O (Input Level Low)
faults.05 ALARM R/O AlarmFlagRange R/O (Input Level High)
faults.06 ALARM R/O AlarmFlagRange R/O (Output Level Low)
faults.07 ALARM R/O AlarmFlagRange R/O (Output Level High)
faults.08 ALARM R/O AlarmFlagRange R/O (10MHz reference)
faults.09 ALARM R/O AlarmFlagRange R/O (AGC/ALC range)
faults.10 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.11 ALARM R/O AlarmFlagRange R/O (Tx simulated)
faults.12 ALARM R/O AlarmFlagRange R/O (VDC range)
faults.13 ALARM R/O AlarmFlagRange R/O (IDC range)
faults.14 ALARM R/O AlarmFlagRange R/O (Alarm log)
faults.15 ALARM R/O AlarmFlagRange R/O (Config data)
faults.16 ALARM R/O AlarmFlagRange R/O (WG switch)
faults.17 ALARM R/O AlarmFlagRange R/O (Input Overdrive)
faults.18 ALARM R/O AlarmFlagRange R/O (Protection)
faults.19 ALARM R/O AlarmFlagRange R/O (Reverse Level high)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)