This page describes the device driver and the device window for the Terrasat Receive Protection / Redundancy switching system.
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The operational parametersConfiguration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| info.model | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.firmware | TEXT | R/O | StringRange R/O |
| info.status | TEXT | R/O | StringRange R/O |
| protection | CHOICE | EnumRange (MANUAL AUTO) | |
| redundancyMode | CHOICE | EnumRange (reverting non-reverting) | |
| location | CHOICE | EnumRange (A B) | |
| position | CHOICE | EnumRange (A B) | |
| meas.voltage.1 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.2 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.current.1 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.current.2 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.power.1 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.power.2 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| reset | TEXT | NOPRESET | StringRange |
| internal.fault1 | CHOICE | R/O | EnumRange R/O (true false) |
| internal.fault2 | CHOICE | R/O | EnumRange R/O (true false) |
| internal.a | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.b | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Low input A) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Low input B) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Simulated alarm A) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Simulated alarm B) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Low voltage A) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Low voltage B) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (High voltage A) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (High voltage B) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Low current A) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Low current B) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (High current A) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (High current B) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (10 MHz) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (Emergency override) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (Switch) |
| faults.16 | ALARM | R/O | AlarmFlagRange R/O (Corrupt log) |
| faults.17 | ALARM | R/O | AlarmFlagRange R/O (Config data) |
| faults.18 | ALARM | R/O | AlarmFlagRange R/O (Protection) |