This page describes the device driver and the device window for the Vertex SCR series upconverter with Ethernet interface in legacy mode (early firmware versions) without support for StarSwitch redundancy switching.
Tested with model:
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The operational parameters
--- Not used with this model.
--- Not used with this model.
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the upconverter.
parameter --- description
address --- The SNMP address specification for the device. The full address specification consists of the following fields:aaa.bbb.ccc.ddd:pppp read-community write-community
powerDisplayMode --- Defines the display of gain or attenuation in the parameter section.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| tx.on | CHOICE | EnumRange (OFF ON) | |
| tx.gain | FLOAT | DoubleRange (1.8 .. 31.8) | |
| tx.attn | FLOAT | DoubleRange (1.8 .. 31.8) | |
| tx.frequency | FLOAT | DoubleRange (13750.000 .. 14500.000) | |
| info.model | TEXT | R/O | StringRange R/O |
| info.temperature | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| info.current | FLOAT | R/O | DoubleRange R/O (0.000 .. 0.000) |
| info.voltage | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.ethVersion | TEXT | R/O | StringRange R/O |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| reset | TEXT | NOPRESET | StringRange |
| internal.model | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.fa | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.fb | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.fc | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.fd | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.sa | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Ref. module) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Front panel) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Power supply) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Ext. ref.) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Temp. Cal.) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Eth. DHCP) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Eth. com.) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (STARswitch) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Logic board) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Temp. high) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Temp. low) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (Invalid freq.) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (Synthesizer) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (Fan) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (TX ON) |