9.778 Work-VSCSR

This page describes the device driver and the device window for the Work Microwave Calibration Source Type VSCSR

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

parameter description
address The device address (decimal) as set at the device's front panel.
Serial Remember to set the line parameters for the serial interface
extMuteInput Defines to disable or enable the input for Hardware Mute (RF-Inhibit).
extRef Defines the reference source.
autoSave Store current parameters automatically in the instrument startup configuration.

Remote Control

Default TCP Port= 50505

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.FrontBaseVersion TEXT R/O StringRange R/O
info.FrontDeviceVersion TEXT R/O StringRange R/O
info.InterfaceVersion TEXT R/O StringRange R/O
info.ReferenceVersion TEXT R/O StringRange R/O
info.SynthesizerVersion TEXT R/O StringRange R/O
info.IfModuleVersion TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.extRef CHOICE SETUP EnumRange (INTERNAL EXTERNAL AUTO)
config.extMuteInput CHOICE SETUP EnumRange (ENABLED DISABLED)
config.autoSave CHOICE SETUP EnumRange (OFF ON)
tx.on CHOICE NOPRESET EnumRange (OFF ON)
meas.extRef BOOLEAN R/O BooleanRange R/O (true false)
meas.extMute BOOLEAN R/O BooleanRange R/O (true false)
temp.controller FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.refBoard FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.synthesizer FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
reset TEXT NOPRESET StringRange
internal.sa0 INTEGER R/O IntegerRange R/O (0 .. 0)
faults.02 ALARM R/O AlarmFlagRange R/O (OCXO oven cold)
faults.03 ALARM R/O AlarmFlagRange R/O (Internal)
faults.04 ALARM R/O AlarmFlagRange R/O (Reference PLL)
faults.05 ALARM R/O AlarmFlagRange R/O (Amplifier)
faults.06 ALARM R/O AlarmFlagRange R/O (MW output)
faults.07 ALARM R/O AlarmFlagRange R/O (Synthesizer)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)