9.796 Zodiac-Cortex-CRT-TMS

This page describes the Zodiac-Cortex-CRT-TMS device driver and its device window. The Zodiac-Cortex-CRT-TMS device driver uses the following tables: Telemetry Simulator. It is based on the STI 100013_CRT remote protocol document v 3.31, dated Jan. 10., 2020

If more than one telemetry simulator is used on the CRT several instances of this driver can be added within the same thread.

Beside the TMS multiple instances of the various functional elements may be configured in the sat-nms M&C to handle all features of the unit. All devices referring to the same physical device must be configured at the same device thread / interface to ensure that TCP requests and commands to the device do not overlap.

The different available module drivers for the CRT are:

The CRT requires two separate IP connection for monitoring and commanding the device. The device driver establishes the connection to the monitoring port (usually 3000) by terminal server like TTY connection. This connection is permanently active. Address and port are set in the vlc.setup configuration file as for a terminal server serial port.
How to use TLS connection is described below.

Steps to configure the Zodiac-CRT drivers / devices for TLS communication

1. Create a PKCS12 keystore from the cert files read from the BBU:

openssl pkcs12 -export -out bbu.p12 \
   -inkey CRT-Services-Client-v2.key -in CRT-Services-Client-v2.cert.pem 

openssl prompts to select a password for keystore. e.g. crt

2. Copy the keystore file to /home/satnms/certs/ at the M&C

3. Edit the device configuration (client) to tell the M&C about the protocol and port.

PORT "TLS:192.168.2.202:53000" PROTOCOL CortexNT
    IDLE 1000
    DEVICE BBU-1 IS Zodiac-Cortex-CRT
    DEVICE BBU-1-IFR-1 IS Zodiac-Cortex-CRT-IFR
    DEVICE BBU-1-IFR-2 IS Zodiac-Cortex-CRT-IFR
    DEVICE BBU-1-IFR-3 IS Zodiac-Cortex-CRT-IFR
    DEVICE BBU-1-IFR-4 IS Zodiac-Cortex-CRT-IFR
    DEVICE BBU-1-IFM-1 IS Zodiac-Cortex-CRT-IFM
    DEVICE BBU-1-IFM-2 IS Zodiac-Cortex-CRT-IFM
    DEVICE BBU-1-TMU-A IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-B IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-C IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-D IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-E IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-F IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-G IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TMU-H IS Zodiac-Cortex-CRT-TMU
    DEVICE BBU-1-TCU-1 IS Zodiac-Cortex-CRT-TCU
    DEVICE BBU-1-TCU-2 IS Zodiac-Cortex-CRT-TCU
    DEVICE BBU-1-TMS-1 IS Zodiac-Cortex-CRT-TMS
    DEVICE BBU-1-TMS-2 IS Zodiac-Cortex-CRT-TMS
    DEVICE BBU-1-PRJ IS Zodiac-Cortex-CRT-PRJ

Important is the TLS in front of the IP address and the port number to use with TLS communication.

4. Restart the M&C and for each BBU-* device edit these setup parameters.

config.cmdPort = 53001
address = certs/bbu.p12 crt

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the device.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.basic TEXT R/O StringRange R/O
info.bw TEXT R/O StringRange R/O
config.cmdPort INTEGER SAVE SETUP IntegerRange (0 .. 0)
config.module CHOICE SAVE SETUP EnumRange (TMS-1 TMS-2)
config.deviceComment TEXT SAVE SETUP StringRange
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
internal.cmd TEXT R/O StringRange R/O
internal.tmsTable HEX R/O HexRange R/O (0 .. 0)
internal.hasTms BOOLEAN R/O BooleanRange R/O (true false)
internal.test INTEGER R/O IntegerRange R/O (0 .. 0)
cmdstat TEXT R/O StringRange R/O
dataFlowId HEX HexRange (0 .. 0)
frequency FLOAT DoubleRange (0.000 .. 0.000)
symbolRate INTEGER IntegerRange (0 .. 0)
operatingMode CHOICE EnumRange (LAN FILE PSEUDO-RANDOM REPLAY-LEGACY BERT BER-RPN REPLAY-SINGLE)
output CHOICE EnumRange (OFF ON)
file INTEGER IntegerRange (1 .. 8)
pcm.code CHOICE EnumRange (BP-L NRZ-L NRZ-M NRZ-S BP-M BP-S DBP-M DBP-S DM-M DM-S R-NRZ NRZ-L-V35 NRZ-M-V35)
formatLength INTEGER IntegerRange (1 .. 32768)
modulation CHOICE EnumRange (NONE BPSK PCM-PM PCM-FM BPSK-SQUARE)
pcm.data CHOICE EnumRange (NORMAL INVERTED)
berFlow CHOICE EnumRange (TM-CH-A TM-CH-B TM-CH-C TM-CH-D TM-CH-E TM-CH-F TM-CH-G TM-CH-H)
encoding CHOICE EnumRange (NONE SCRAMBLING G2-INV G2 G2-INV-SCRAMBLING G2-SCRAMBLING)
encodingRate CHOICE EnumRange (1/2 1/3 2/3 3/4-CONV1 3/4-CONV2 5/6-CONV1 5/6-CONV1 7/8)
frame.check CHOICE EnumRange (OFF ON)
frame.coding CHOICE EnumRange (NONE RS232-BETA TURBO RS232-ALPHA LDPC TPC RS239-BETA RS239-ALPHA)
pcm.modSignal CHOICE EnumRange (INTERNAL EXTERNAL)
pcm.clock CHOICE EnumRange (INTERNAL EXTERNAL)
frequencyDeviation INTEGER IntegerRange (0 .. 300000)
modulationIndex FLOAT DoubleRange (0.00 .. 2.50)
doppler.enable CHOICE EnumRange (OFF ON)
prn CHOICE EnumRange (STANDARD 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23)
replay INTEGER IntegerRange (0 .. 0)
state.ber FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
format.tm1 HEX R/O HexRange R/O (0 .. 0)
format.tm2 HEX R/O HexRange R/O (0 .. 0)
format.tm3 HEX R/O HexRange R/O (0 .. 0)
format.tm4 HEX R/O HexRange R/O (0 .. 0)
format.tm5 HEX R/O HexRange R/O (0 .. 0)
format.tm6 HEX R/O HexRange R/O (0 .. 0)
format.tm7 HEX R/O HexRange R/O (0 .. 0)
format.tm8 HEX R/O HexRange R/O (0 .. 0)
format.id INTEGER R/O IntegerRange R/O (0 .. 0)
state.bytesLan INTEGER R/O IntegerRange R/O (0 .. 0)
state.doppler TEXT R/O StringRange R/O
state.sampling TEXT R/O StringRange R/O
state.berCount INTEGER R/O IntegerRange R/O (0 .. 0)
state.fileId INTEGER R/O IntegerRange R/O (0 .. 0)
state.fileProgress INTEGER R/O IntegerRange R/O (0 .. 0)
state.filetoReplay INTEGER R/O IntegerRange R/O (0 .. 0)
state.activeTestpoint TEXT R/O StringRange R/O
resetBer TEXT NOPRESET StringRange
injectError TEXT NOPRESET StringRange
start TEXT NOPRESET StringRange
stop TEXT NOPRESET StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Ext Clock)
faults.02 ALARM R/O AlarmFlagRange R/O (Overflow)
faults.03 ALARM R/O AlarmFlagRange R/O (File)
faults.04 ALARM R/O AlarmFlagRange R/O (Create Configuration)
faults.05 ALARM R/O AlarmFlagRange R/O (Encoding)