This page describes the device driver and the device window for the Advantech Wireless BUC via GCP (General Control panel). The SSPB itself does not provide a Ethernet interface. Therefore the driver talks with the GCP via SNMP. If more than one BUC is connected to the same Control panel the respective unit can be chosen from the device setup config.unit.
It was tested with non redundant ARMA type 160W HPAs
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The operational parameters
--- The meter readings.
--- The redundancy switching parameters.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| info.version | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.powerClass | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| info.serialCtrl | TEXT | R/O | StringRange R/O |
| info.shroudTemp | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| info.voltagePsu1Ctrl | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| info.voltagePsu2Ctrl | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| info.elapsedTime | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.unit | CHOICE | SAVE SETUP | EnumRange (1 2 3 4 5 6) |
| config.redundancy | CHOICE | SAVE SETUP | EnumRange (STANDALONE 1:1 2:1) |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| config.accessMode | CHOICE | SETUP | EnumRange (LOCAL REMOTE) |
| config.accessLock | CHOICE | SETUP | EnumRange (UNLOCKED LOCKED) |
| config.extRef | CHOICE | SETUP | EnumRange (INTERNAL EXTERNAL) |
| config.reference | CHOICE | SETUP | EnumRange (MANUAL AUTO) |
| config.deviceComment | TEXT | SAVE SETUP | StringRange |
| tx.on | CHOICE | EnumRange (OFF ON) | |
| tx.gain | FLOAT | DoubleRange (0.0 .. 16.0) | |
| tx.attn | FLOAT | DoubleRange (0.0 .. 16.0) | |
| tx.alc | CHOICE | EnumRange (ON OFF) | |
| meas.fwdPwr | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.refPwr | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| tx.measuredLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.measuredLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.temperature | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.hotspotTemp | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.current | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| protection | CHOICE | EnumRange (MANUAL AUTO) | |
| location | CHOICE | R/O | EnumRange R/O (STANDBY ONLINE) |
| position | CHOICE | EnumRange DIS (A B) | |
| online | TEXT | NOPRESET | StringRange DIS |
| onlineA | TEXT | NOPRESET | StringRange DIS |
| onlineB | TEXT | NOPRESET | StringRange DIS |
| reset | TEXT | NOPRESET | StringRange |
| internal.min | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.max | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.on | TEXT | R/O | StringRange R/O |
| internal.pout | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.pref | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Units Positions) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Transmit shutdown) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (No Communication) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (TX Fault) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (TX Alarm) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Reflected Power) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (ALC High) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (ALC Low) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (TX Switch) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (TX SW Connected) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Reference) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (TX Off) |