1.32 Advantech-SSPB-MCP

This page describes the device driver and the device window for the Advantech Wireless BUC via a Monitor and control panel M&C 100 over serial interface. It uses the Advantech MCP protocol.

Default serial addresses are as following for 2:1 redundancy

It was tested with 2:1 redundant SSPAs type: SSPA-ARMA-Cx400

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address Device address for serial communication
Serial Remember to set the line parameters for the serial interface
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.powerClass INTEGER IntegerRange (0 .. 0)
info.band TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
info.unit TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
tx.on CHOICE EnumRange (OFF ON)
tx.attn FLOAT DoubleRange (0.0 .. 16.0)
tx.attn.1 FLOAT DoubleRange DIS (0.0 .. 16.0)
tx.attn.2 FLOAT DoubleRange DIS (0.0 .. 16.0)
tx.alc CHOICE EnumRange (OFF ON)
tx.requestedLevel FLOAT DoubleRange (0.0 .. 0.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.hotspotTemp FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.current INTEGER R/O IntegerRange R/O (0 .. 0)
protection CHOICE EnumRange (MANUAL AUTO)
location CHOICE EnumRange (STANDBY ONLINE)
position.1 TEXT NOPRESET StringRange DIS
position.2 TEXT NOPRESET StringRange DIS
reset TEXT NOPRESET StringRange
internal.min FLOAT DoubleRange (0.0 .. 0.0)
internal.max FLOAT DoubleRange (0.0 .. 0.0)
internal.forwardPower TEXT R/O StringRange R/O
internal.on TEXT R/O StringRange R/O
internal.pout FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.pref FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.1 TEXT R/O StringRange R/O
internal.2 TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (PA Device)
faults.02 ALARM R/O AlarmFlagRange R/O (Fault shutdown)
faults.03 ALARM R/O AlarmFlagRange R/O (Summary)
faults.04 ALARM R/O AlarmFlagRange R/O (Reflected Pwr)
faults.05 ALARM R/O AlarmFlagRange R/O (ALC Suspended)
faults.06 ALARM R/O AlarmFlagRange R/O (ALC High)
faults.07 ALARM R/O AlarmFlagRange R/O (ALC Low)
faults.10 ALARM R/O AlarmFlagRange R/O (Protection)
faults.11 ALARM R/O AlarmFlagRange R/O (Switch 1)
faults.12 ALARM R/O AlarmFlagRange R/O (Switch 2)
faults.13 ALARM R/O AlarmFlagRange R/O (Switch 3)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)