1.236 Evertz-7707-LR

This page describes the device driver and the device window for the Evertz 7800 Chassis LR7707 Series 70/140MHz Receiver cards type:

The driver was tested with the following cards:

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.squelch CHOICE SETUP EnumRange (ON OFF)
config.slot CHOICE SAVE SETUP EnumRange (2 3 4 5 6 7 8 9 10 11 12 13 14 15)
optLowThreshold INTEGER IntegerRange (-33 .. 3)
optHighThreshold INTEGER IntegerRange (-33 .. 4)
rfLowThreshold INTEGER IntegerRange (-35 .. -4)
rfHighThreshold INTEGER IntegerRange (-35 .. -4)
optPower INTEGER R/O IntegerRange R/O (0 .. 0)
rfPower INTEGER R/O IntegerRange R/O (0 .. 0)
partnerTxPower INTEGER R/O IntegerRange R/O (0 .. 0)
rx.gain CHOICE EnumRange (AUTO 10dB 20dB 30dB)
faults.01 ALARM R/O AlarmFlagRange R/O (Opt Pwr Low)
faults.02 ALARM R/O AlarmFlagRange R/O (Opt Pwr High)
faults.03 ALARM R/O AlarmFlagRange R/O (RF Out Low)
faults.04 ALARM R/O AlarmFlagRange R/O (RF Out High)
faults.05 ALARM R/O AlarmFlagRange R/O (Remote Access)
card.name TEXT SAVE StringRange
internal.model TEXT StringRange