This page describes the device driver and the device window for the Evertz 7800 Chassis LT7707 Series 70/140MHz transmitter cards type:
The driver was tested with the following cards:
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- Shows all parameters of the LT card.
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.
parameter --- description
address --- The SNMP address specification for the device. The full address specification consists of the following fields:aaa.bbb.ccc.ddd:pppp read-community write-community
lnbVoltage --- Defines the lnb supply voltage for suitable cards
lnb --- Enable lnb supply for suitable cards.
slot --- Defines the slot number where the card is installed. Setting this parameter is indispensable for correct communication
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.model | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.lnbVoltage | CHOICE | R/O | EnumRange R/O (OFF LOW HIGH) |
| config.lnb | CHOICE | R/O | EnumRange R/O (ON OFF) |
| config.slot | CHOICE | SAVE SETUP | EnumRange (2 3 4 5 6 7 8 9 10 11 12 13 14 15) |
| optCurrent | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| rfPower | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| rfLowThreshold | INTEGER | IntegerRange (0 .. 0) | |
| rfHighThreshold | INTEGER | IntegerRange (0 .. 0) | |
| tx.gain | CHOICE | EnumRange (AUTO 0dB 10dB 15dB) | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Laser Failed) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Laser Degraded) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (RF In Low) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (RF In High) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Remote Access) |
| card.name | TEXT | SAVE | StringRange |
| internal.model | TEXT | StringRange |