This page describes the device driver and the device window for the Geosync 1:2 Redundant switchover system series: R2R-S50/S50
It was tested with:
The following table shows which device window pages are available with this individual device type.
--- The operational parameters
--- The monitoring parameters
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel as ASCII-character (e.g. @ for 64dec). |
| readBackDelay | Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances. |
| cableComp.1 | Defines the cable compensation for unit 1. |
| cableComp.2 | Defines the cable compensation for unit 2. |
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.model | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.cableComp.1 | FLOAT | SETUP | DoubleRange (0.0 .. 0.0) |
| config.cableComp.2 | FLOAT | SETUP | DoubleRange (0.0 .. 0.0) |
| meas.voltage.1 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.2 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.3 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.4 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.model | TEXT | StringRange | |
| internal.dummy | TEXT | StringRange | |
| protection | CHOICE | EnumRange (MANUAL AUTO) | |
| position | CHOICE | EnumRange (3-STBY 1-STBY 2-STBY) | |
| position.1 | CHOICE | R/O | EnumRange R/O (A B) |
| position.2 | CHOICE | R/O | EnumRange R/O (A B) |
| priority.1 | CHOICE | EnumRange (HIGH LOW) | |
| priority.2 | CHOICE | EnumRange (HIGH LOW) | |
| tx.attn.0 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| tx.attn.1 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| tx.attn.2 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| if.attn.0 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| if.attn.1 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| if.attn.2 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| slope.0 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| slope.1 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| slope.2 | FLOAT | DoubleRange (0.0 .. 0.0) | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Power supply A) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Power supply B) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Converter Comms) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Converter Contacts) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Switch) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Protection) |