1.269 Geosync-RCU-R2R

This page describes the device driver and the device window for the Geosync 1:2 Redundant switchover system series: R2R-S50/S50

It was tested with:

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The device address (decimal) as set at the device's front panel as ASCII-character (e.g. @ for 64dec).
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.
cableComp.1 Defines the cable compensation for unit 1.
cableComp.2 Defines the cable compensation for unit 2.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.cableComp.1 FLOAT SETUP DoubleRange (0.0 .. 0.0)
config.cableComp.2 FLOAT SETUP DoubleRange (0.0 .. 0.0)
meas.voltage.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.3 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.4 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.model TEXT StringRange
internal.dummy TEXT StringRange
protection CHOICE EnumRange (MANUAL AUTO)
position CHOICE EnumRange (3-STBY 1-STBY 2-STBY)
position.1 CHOICE R/O EnumRange R/O (A B)
position.2 CHOICE R/O EnumRange R/O (A B)
priority.1 CHOICE EnumRange (HIGH LOW)
priority.2 CHOICE EnumRange (HIGH LOW)
tx.attn.0 FLOAT DoubleRange (0.0 .. 0.0)
tx.attn.1 FLOAT DoubleRange (0.0 .. 0.0)
tx.attn.2 FLOAT DoubleRange (0.0 .. 0.0)
if.attn.0 FLOAT DoubleRange (0.0 .. 0.0)
if.attn.1 FLOAT DoubleRange (0.0 .. 0.0)
if.attn.2 FLOAT DoubleRange (0.0 .. 0.0)
slope.0 FLOAT DoubleRange (0.0 .. 0.0)
slope.1 FLOAT DoubleRange (0.0 .. 0.0)
slope.2 FLOAT DoubleRange (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Power supply A)
faults.03 ALARM R/O AlarmFlagRange R/O (Power supply B)
faults.04 ALARM R/O AlarmFlagRange R/O (Converter Comms)
faults.05 ALARM R/O AlarmFlagRange R/O (Converter Contacts)
faults.06 ALARM R/O AlarmFlagRange R/O (Switch)
faults.07 ALARM R/O AlarmFlagRange R/O (Protection)