This page describes the device driver and the device window for the Geosync LNA/LNB redundancy controller
Device window pages
The following table shows which device window pages are available with this individual device type.
--- The operational parameters
--- The monitoring parametersConfiguration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.
| parameter | description |
|---|---|
| address | The device address (decimal) as set at the device's front panel. |
| Serial | Remember to set the line parameters for the serial interface |
Remarks
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.model | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.iLowLimit.1 | INTEGER | SETUP | IntegerRange (0 .. 500) |
| config.iHighLimit.1 | INTEGER | SETUP | IntegerRange (0 .. 500) |
| config.iLowLimit.2 | INTEGER | SETUP | IntegerRange (0 .. 500) |
| config.iHighLimit.2 | INTEGER | SETUP | IntegerRange (0 .. 500) |
| config.iLowLimit.3 | INTEGER | SETUP | IntegerRange (0 .. 500) |
| config.iHighLimit.3 | INTEGER | SETUP | IntegerRange (0 .. 500) |
| config.lnaVoltage | CHOICE | SETUP | EnumRange (12V 15V) |
| meas.current.1 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.current.2 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.current.3 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.voltage.1 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.2 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.3 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.voltage.4 | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.model | TEXT | StringRange | |
| internal.dummy | TEXT | StringRange | |
| protection | CHOICE | EnumRange (MANUAL AUTO) | |
| priority | CHOICE | EnumRange (NONE LNA1 LNA2) | |
| position | CHOICE | EnumRange (3-STBY 1-STBY 2-STBY) | |
| position.1 | CHOICE | EnumRange (A B) | |
| position.2 | CHOICE | EnumRange (A B) | |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Remote access) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Amplifier) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Switch) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Power supply) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (LNA/LNB1) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (LNA/LNB2) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (LNA/LNB3) |