1.295 Hitec-AFP-Deice

This page describes the monitoring only device driver and the device window for the Hitec Antenna Front Panel. The driver covers the De-icing related parameters.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The device address (decimal) as set at the device's front panel.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
deice.status CHOICE EnumRange (OFF AUTOMATIC)
deice.auto CHOICE EnumRange (OFF ON)
deice.remote BOOLEAN R/O BooleanRange R/O (true false)
deice.requested BOOLEAN R/O BooleanRange R/O (true false)
feedblower.status CHOICE R/O EnumRange R/O (OFF ON)
state.rain BOOLEAN R/O BooleanRange R/O (true false)
feedblower.remote BOOLEAN R/O BooleanRange R/O (true false)
deice.a BOOLEAN R/O BooleanRange R/O (true false)
deice.b BOOLEAN R/O BooleanRange R/O (true false)
deice.c BOOLEAN R/O BooleanRange R/O (true false)
deice.subref BOOLEAN R/O BooleanRange R/O (true false)
temp.outsite FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.aped FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.ahub FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.driveCabinet FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.fanDriveCabinet FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.waterTank FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
humidity.outsite FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
humidity.aped FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
humidity.ahub FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.04 ALARM R/O AlarmFlagRange R/O (RF Summary)
faults.05 ALARM R/O AlarmFlagRange R/O (HVAC Summary)
faults.06 ALARM R/O AlarmFlagRange R/O (Deicing Summary)
faults.10 ALARM R/O AlarmFlagRange R/O (Feed blower fuse)
faults.11 ALARM R/O AlarmFlagRange R/O (Feed blower)
faults.12 ALARM R/O AlarmFlagRange R/O (Deicing fuse)
faults.13 ALARM R/O AlarmFlagRange R/O (High Subref.Temp.)
faults.14 ALARM R/O AlarmFlagRange R/O (Deicing trapech)
faults.20 ALARM R/O AlarmFlagRange R/O (Protection)
faults.21 ALARM R/O AlarmFlagRange R/O (Remote Access)
internal.r INTEGER R/O IntegerRange R/O (0 .. 0)