1.301 Hitec-HAFP-00

This page describes the monitoring only device driver and the device window for the Hitec antenna front panel including deicing parameters, temperatures and different summary alarms. ACU parameters are not included as they are implemented directly in Hitec-HACU-01 device

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The device address (decimal) as set at the device's front panel.
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
deice.status CHOICE EnumRange (OFF AUTOMATIC)
deice.auto CHOICE EnumRange (OFF ON)
deice.remote BOOLEAN R/O BooleanRange R/O (true false)
deice.requested BOOLEAN R/O BooleanRange R/O (true false)
feedblower.status CHOICE R/O EnumRange R/O (OFF ON)
state.rain BOOLEAN R/O BooleanRange R/O (true false)
deice.a BOOLEAN R/O BooleanRange R/O (true false)
deice.b BOOLEAN R/O BooleanRange R/O (true false)
deice.c BOOLEAN R/O BooleanRange R/O (true false)
deice.d BOOLEAN R/O BooleanRange R/O (true false)
deice.subref BOOLEAN R/O BooleanRange R/O (true false)
temp.outsite FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.aped FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.ahub FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.driveCabinet FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
temp.powerCabinet FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
humidity.outsite FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
humidity.aped FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
humidity.ahub FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (Emergency stop)
faults.02 ALARM R/O AlarmFlagRange R/O (Drive Summary)
faults.03 ALARM R/O AlarmFlagRange R/O (General Summary)
faults.04 ALARM R/O AlarmFlagRange R/O (RF Summary)
faults.05 ALARM R/O AlarmFlagRange R/O (Climatic Summary)
faults.06 ALARM R/O AlarmFlagRange R/O (Deicing Summary)
faults.07 ALARM R/O AlarmFlagRange R/O (Access Summary)
faults.09 ALARM R/O AlarmFlagRange R/O (Final Limit)
faults.10 ALARM R/O AlarmFlagRange R/O (Rain blower fuse)
faults.11 ALARM R/O AlarmFlagRange R/O (Rain blower)
faults.12 ALARM R/O AlarmFlagRange R/O (Deicing fuse)
faults.14 ALARM R/O AlarmFlagRange R/O (Deicing surge protect)
faults.20 ALARM R/O AlarmFlagRange R/O (Deicing off)
faults.21 ALARM R/O AlarmFlagRange R/O (Remote Access)
faults.22 ALARM R/O AlarmFlagRange R/O (APED 1 Fuse)
faults.23 ALARM R/O AlarmFlagRange R/O (APED 2 Fuse)
internal.r INTEGER R/O IntegerRange R/O (0 .. 0)