1.539 Protection-Switch-N-To-M

The Protection-Switch-N-To-M logical device builds together with a set of protection controller devices a n:m redundancy solution for satellite modulators, downconverters etc.

This solution supports a pool of backup devices from which one device is taken in case of failure of an operative device. In case of a redundancy switch all parameters are mirrored to the spare device.

Actually there are two typed of protection controller devices available:

The devices managed by Protection-Switch-N-To-M device must be all of the same type, to make an 1:1 parmeter mirroring to the spare device work properly, the manufacturer and model type should also be the same

For n:m redundancy, one Protection-Switch-N-To-M device and for each managed modulator a protection controller device are configured in the M&C device setup. This distribution across two device types enables a very flexible configuration of the redundancy, so there is no explicit limit on the number of managed modulators.

The Protection-Switch-N-To-M device, as the central instance of the redundancy switch, manages the pool of modems (which are operational, which are spare). It defines the name of the switching matrix that routes the outputs of the modulators as well as parameters shared by the modem protection controller devices as configuration parameters.

The device's operational parameters are:

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there is one configuration parameter which must be set to interconnect the redundancy switch with the devices it shall monitor and control.

parameter description
matrix The name of the switch matrix which routes the outputs of all managed modulators to the transmit equipment.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.freeSpares INTEGER R/O IntegerRange R/O (0 .. 0)
config.matrix TEXT SAVE SETUP StringRange
protection CHOICE SAVE EnumRange (OFF ON)
state TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Matrix)
faults.02 ALARM R/O AlarmFlagRange R/O (Protection)
faults.03 ALARM R/O AlarmFlagRange R/O (No spare available)
faults.04 ALARM R/O AlarmFlagRange R/O (Mixed controllers)