9.34 Advantech-SSPB

This page describes the device driver and the device window for the Advantech Wireless BUC over serial interface.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address Device address for serial communication
Serial Remember to set the line parameters for the serial interface (only if connected to serial port of beacon receiver and not to Ethernet)
readBackDelay Defines the delay the driver uses when it reads back parameters recently commanded. The delay is initialized at a proved preset value which should not be changed under normal circumstances.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.extRef TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.powerClass INTEGER IntegerRange (0 .. 0)
info.redundancy TEXT R/O StringRange R/O
info.band TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 16.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.current INTEGER R/O IntegerRange R/O (0 .. 0)
protection CHOICE EnumRange DIS (MANUAL AUTO)
location CHOICE EnumRange DIS (STANDBY ONLINE)
position CHOICE EnumRange DIS (A B)
onSwitch CHOICE R/O EnumRange R/O DIS (attached as A attached as B)
reset TEXT NOPRESET StringRange
internal.min FLOAT DoubleRange (0.0 .. 0.0)
internal.max FLOAT DoubleRange (0.0 .. 0.0)
internal.forwardPower TEXT R/O StringRange R/O
internal.on TEXT R/O StringRange R/O
internal.pout FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.pref FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
faults.01 ALARM R/O AlarmFlagRange R/O (PA Device)
faults.02 ALARM R/O AlarmFlagRange R/O (Temperature Alarm)
faults.03 ALARM R/O AlarmFlagRange R/O (Temperature Pre Alarm)
faults.04 ALARM R/O AlarmFlagRange R/O (RF Alarm)
faults.05 ALARM R/O AlarmFlagRange R/O (Tx Alarm)
faults.10 ALARM R/O AlarmFlagRange R/O (Summary)
faults.26 ALARM R/O AlarmFlagRange R/O (TX Off)