9.147 Comtech-UT4500

This page describes the device driver and the device window for the Comtech upconverter series UT4500 with serial interface and support for the internal 1+1 redundancy.

The driver detects the model name and adapts the frequency range.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Upconverter.

parameter description
address The device address (decimal) as set at the device's front panel.
Serial Remember to set the line parameters for the serial interface

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.15vdc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.14vdc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.vcc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.5vdc FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.temperature INTEGER R/O IntegerRange R/O (0 .. 0)
info.ifloTuning FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.sumLoopTuning FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.coarseLoopTuning FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.fineLoopTuning FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.converterNumber TEXT R/O StringRange R/O
info.chainLength TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.autoFaultRecovery CHOICE SETUP EnumRange (ON OFF)
config.coldStart CHOICE SETUP EnumRange (ON OFF)
config.refFreqAdjustment INTEGER SETUP IntegerRange (0 .. 0)
config.slopeAdjustment FLOAT SETUP DoubleRange (0.0 .. 0.0)
config.redundancy CHOICE SETUP EnumRange (ON OFF)
config.freqLength CHOICE SAVE SETUP EnumRange (4 5 7)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.00 .. 25.00)
tx.attn FLOAT DoubleRange (0.00 .. 25.00)
tx.frequency FLOAT DoubleRange (0.000 .. 0.000)
protection CHOICE EnumRange DIS (MANUAL AUTO)
state CHOICE R/O EnumRange R/O (OFFLINE ONLINE)
location CHOICE EnumRange DIS (NONE 01)
switched BOOLEAN R/O BooleanRange R/O (true false)
reset TEXT NOPRESET StringRange
internal.oldloc TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (15 VDC)
faults.03 ALARM R/O AlarmFlagRange R/O (14 VDC)
faults.04 ALARM R/O AlarmFlagRange R/O (VCC)
faults.05 ALARM R/O AlarmFlagRange R/O (5VD)
faults.06 ALARM R/O AlarmFlagRange R/O (Temperature)
faults.07 ALARM R/O AlarmFlagRange R/O (IFLO Lock)
faults.08 ALARM R/O AlarmFlagRange R/O (Sum Lock)
faults.09 ALARM R/O AlarmFlagRange R/O (Coarse Lock)
faults.10 ALARM R/O AlarmFlagRange R/O (Fine Lock)
faults.11 ALARM R/O AlarmFlagRange R/O (High Speed Bus)
faults.12 ALARM R/O AlarmFlagRange R/O (Ref Lock)
faults.13 ALARM R/O AlarmFlagRange R/O (Cold start)
faults.14 ALARM R/O AlarmFlagRange R/O (Ext. Reference)