9.96 CPI-VZU-TWTA

This page describes the device driver and the device window for the CPI VZU TWT amplifiers. The driver has been tested with the following model: VZU6995F (via CIM VJW2740092)

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the Amplifier.

parameter description
address The device address (decimal). While communicating via CIM the first HPA's address is 65 (A) and the second HPA's address is 66 (B).
Serial Remember to set the line parameters for the serial interface connected to the TWTA. The factory default of the HPA is 9600,E,7,1 .

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.summary TEXT R/O StringRange R/O
info.s1 TEXT R/O StringRange R/O
info.signal.on BOOLEAN R/O BooleanRange R/O (true false)
tx.beam CHOICE EnumRange (STANDBY ON)
reset TEXT NOPRESET StringRange
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 80.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
internal.summ1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.summ2 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.beam INTEGER R/O IntegerRange R/O (0 .. 0)
faults.02 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.04 ALARM R/O AlarmFlagRange R/O (High reflected power)
faults.05 ALARM R/O AlarmFlagRange R/O (Power peak indicate)
faults.06 ALARM R/O AlarmFlagRange R/O (Heater not ready)