9.402 NAIS-FP-TxOn-Switch

This page describes the device driver and the device window for the NAIS-FP-TxOn-Switch device. This device controls a NAiS/Matsushita PLC running a program that switches the tx switch if two alarms (e.g. from satellite modems) are active longer than 15 minutes. The PLC recognizes two device alarms and controls one waveguide switch. The driver exclusively works with a PLC programmed in this special way.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the alarm monitoring input at the PLC.

parameter description
address The packet address of the PLC device. Usually this is "01".
Serial Remember to set the line parameters for the serial interface connected to the FPx PLC device. It requires the somewhat unusual setting 9600,O,8,1 . With multiple NAIS-FP-* -devices referring to the same PLC, the line speed needs to be setup only once.

Remarks

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
position CHOICE EnumRange (ENABLED DISABLED)
reset TEXT StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Has switched)