This page describes the device driver and the device window for the Newtec FRC0750 block upconverter.
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- Device settings and status display
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the FRC0750
parameter --- description
address --- The SNMP address specification for the device. The full address specification consists of the following fields:aaa.bbb.ccc.ddd:pppp read-community write-community
rfHiThreshold --- The level threshold for the 'Output overload' fault.
rfLoThreshold --- The level threshold for the 'Output underload' fault.
rfHiFault --- Configures the device whether to signal an 'Output overload' fault if the output level exceeds the threshold value.
rfLoFault --- Configures the device whether to signal an 'Output underload' fault if the output level falls below the threshold value (The device only signals this fault if the output is enabled and at least one input is switched on).
autoSave --- Switching this to YES makes the driver automatically save the device configuration into it's flash memory after every change. NO disables automatic saving, you may use the 'SAVE BOOT CONFIG' button in the sat-nms GUI to save the actual configuration explicitly.
Parameter storage in the FRC0750
Any changes made to the parameters of the FRC0750 only are valid until the device reboots - unless they are stored into the 'boot configuration' flash memory of the device.
The sat-nms driver provides two methods to handle this: In automatic mode the driver commands a 'save boot configuration' after each change made to a parameter. In manual mode, you have to store the parameter by clicking the 'SAVE BOOT CONFIG' button in the sat-nms GUI to save the actual configuration explicitly.
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.model | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| info.deviceName | TEXT | R/O | StringRange R/O |
| info.rfFreqRange | TEXT | R/O | StringRange R/O |
| info.loFrequency | FLOAT | R/O | DoubleRange R/O (0.000 .. 0.000) |
| info.temperature | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| config.rfHiThresh | FLOAT | SETUP | DoubleRange (0 .. 0) |
| config.rfLoThresh | FLOAT | SETUP | DoubleRange (0 .. 0) |
| config.rfHiFault | CHOICE | SETUP | EnumRange (DISABLED ENABLED) |
| config.rfLoFault | CHOICE | SETUP | EnumRange (DISABLED ENABLED) |
| config.inputs | CHOICE | SAVE SETUP | EnumRange (4 8) |
| config.autoSave | CHOICE | SETUP | EnumRange (NO YES) |
| config.deviceComment | TEXT | SAVE SETUP | StringRange |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| rfOut.on | CHOICE | EnumRange (OFF ON) | |
| rfOut.gain | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| lbOut.on | CHOICE | EnumRange (OFF ON) | |
| input.1.on | CHOICE | EnumRange (OFF ON) | |
| input.1.gain | FLOAT | DoubleRange (-30.0 .. 10.0) | |
| input.2.on | CHOICE | EnumRange (OFF ON) | |
| input.2.gain | FLOAT | DoubleRange (-30.0 .. 10.0) | |
| input.3.on | CHOICE | EnumRange (OFF ON) | |
| input.3.gain | FLOAT | DoubleRange (-30.0 .. 10.0) | |
| input.4.on | CHOICE | EnumRange (OFF ON) | |
| input.4.gain | FLOAT | DoubleRange (-30.0 .. 10.0) | |
| input.5.on | CHOICE | EnumRange DIS (OFF ON) | |
| input.5.gain | FLOAT | DoubleRange DIS (-30.0 .. 10.0) | |
| input.6.on | CHOICE | EnumRange DIS (OFF ON) | |
| input.6.gain | FLOAT | DoubleRange DIS (-30.0 .. 10.0) | |
| input.7.on | CHOICE | EnumRange DIS (OFF ON) | |
| input.7.gain | FLOAT | DoubleRange DIS (-30.0 .. 10.0) | |
| input.8.on | CHOICE | EnumRange DIS (OFF ON) | |
| input.8.gain | FLOAT | DoubleRange DIS (-30.0 .. 10.0) | |
| state.rfOut | BOOLEAN | R/O | BooleanRange R/O (true false) |
| state.lbOut | BOOLEAN | R/O | BooleanRange R/O (true false) |
| state.rfOutLevel | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| saveBootConfig | TEXT | NOPRESET | StringRange |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Device reset flag) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Self test) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (Incompatibility) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (General device) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Reference clock) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Device temperature) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (Power supply voltage) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (RF upconverter DRO) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Output overload) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Output underload) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Internal M&C module) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Combiner module 1) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (Upconv-Cond. module) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (Device architecture) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (Internal communication) |
| internal.save | TEXT | R/O | StringRange R/O |