9.451 Newtec-FRC0750

This page describes the device driver and the device window for the Newtec FRC0750 block upconverter.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the FRC0750

Parameter storage in the FRC0750

Any changes made to the parameters of the FRC0750 only are valid until the device reboots - unless they are stored into the 'boot configuration' flash memory of the device.

The sat-nms driver provides two methods to handle this: In automatic mode the driver commands a 'save boot configuration' after each change made to a parameter. In manual mode, you have to store the parameter by clicking the 'SAVE BOOT CONFIG' button in the sat-nms GUI to save the actual configuration explicitly.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.deviceName TEXT R/O StringRange R/O
info.rfFreqRange TEXT R/O StringRange R/O
info.loFrequency FLOAT R/O DoubleRange R/O (0.000 .. 0.000)
info.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.rfHiThresh FLOAT SETUP DoubleRange (0 .. 0)
config.rfLoThresh FLOAT SETUP DoubleRange (0 .. 0)
config.rfHiFault CHOICE SETUP EnumRange (DISABLED ENABLED)
config.rfLoFault CHOICE SETUP EnumRange (DISABLED ENABLED)
config.inputs CHOICE SAVE SETUP EnumRange (4 8)
config.autoSave CHOICE SETUP EnumRange (NO YES)
config.deviceComment TEXT SAVE SETUP StringRange
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
rfOut.on CHOICE EnumRange (OFF ON)
rfOut.gain FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
lbOut.on CHOICE EnumRange (OFF ON)
input.1.on CHOICE EnumRange (OFF ON)
input.1.gain FLOAT DoubleRange (-30.0 .. 10.0)
input.2.on CHOICE EnumRange (OFF ON)
input.2.gain FLOAT DoubleRange (-30.0 .. 10.0)
input.3.on CHOICE EnumRange (OFF ON)
input.3.gain FLOAT DoubleRange (-30.0 .. 10.0)
input.4.on CHOICE EnumRange (OFF ON)
input.4.gain FLOAT DoubleRange (-30.0 .. 10.0)
input.5.on CHOICE EnumRange DIS (OFF ON)
input.5.gain FLOAT DoubleRange DIS (-30.0 .. 10.0)
input.6.on CHOICE EnumRange DIS (OFF ON)
input.6.gain FLOAT DoubleRange DIS (-30.0 .. 10.0)
input.7.on CHOICE EnumRange DIS (OFF ON)
input.7.gain FLOAT DoubleRange DIS (-30.0 .. 10.0)
input.8.on CHOICE EnumRange DIS (OFF ON)
input.8.gain FLOAT DoubleRange DIS (-30.0 .. 10.0)
state.rfOut BOOLEAN R/O BooleanRange R/O (true false)
state.lbOut BOOLEAN R/O BooleanRange R/O (true false)
state.rfOutLevel FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
saveBootConfig TEXT NOPRESET StringRange
faults.01 ALARM R/O AlarmFlagRange R/O (Device reset flag)
faults.02 ALARM R/O AlarmFlagRange R/O (Self test)
faults.03 ALARM R/O AlarmFlagRange R/O (Incompatibility)
faults.04 ALARM R/O AlarmFlagRange R/O (General device)
faults.05 ALARM R/O AlarmFlagRange R/O (Reference clock)
faults.06 ALARM R/O AlarmFlagRange R/O (Device temperature)
faults.07 ALARM R/O AlarmFlagRange R/O (Power supply voltage)
faults.08 ALARM R/O AlarmFlagRange R/O (RF upconverter DRO)
faults.09 ALARM R/O AlarmFlagRange R/O (Output overload)
faults.10 ALARM R/O AlarmFlagRange R/O (Output underload)
faults.11 ALARM R/O AlarmFlagRange R/O (Internal M&C module)
faults.12 ALARM R/O AlarmFlagRange R/O (Combiner module 1)
faults.13 ALARM R/O AlarmFlagRange R/O (Upconv-Cond. module)
faults.14 ALARM R/O AlarmFlagRange R/O (Device architecture)
faults.15 ALARM R/O AlarmFlagRange R/O (Internal communication)
internal.save TEXT R/O StringRange R/O