9.475 Novella-RU04

This page describes the device driver and the device window for Novella RU04 2:1 Redundancy Controller for Blockup- and downconverters via SNMP.

It was tested with SW version 97-6050/V1.0

The Novella RU03 covers units in 2:1 redundancy.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the controller.

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.name TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.version TEXT R/O StringRange R/O
info.description TEXT R/O StringRange R/O
config.ctrlMode CHOICE SETUP EnumRange (REMOTE LOCAL)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.deviceComment TEXT SAVE SETUP StringRange
position CHOICE EnumRange (3-STBY 1-STBY 2-STBY)
position.1 CHOICE R/O EnumRange R/O (A B)
position.2 CHOICE R/O EnumRange R/O (A B)
protection CHOICE EnumRange (AUTO MANUAL)
internal.f1 TEXT R/O StringRange R/O
internal.f2 TEXT R/O StringRange R/O
internal.f3 TEXT R/O StringRange R/O
faults.01 ALARM R/O AlarmFlagRange R/O (Unit 1)
faults.02 ALARM R/O AlarmFlagRange R/O (Unit 2)
faults.03 ALARM R/O AlarmFlagRange R/O (Unit 3)
faults.04 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.05 ALARM R/O AlarmFlagRange R/O (Protection)