9.476 Novella-Tracking-Receiver

This page describes the device driver and the device window for the Novella tracking or beacon receiver (L,C,X and/or Ku-Band).

The driver detects the model name and adapts the frequency range.

Device window pages

The following table shows which device window pages are available with this individual device type.

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit.

parameter description
address The device address (decimal) as set at the device's front panel.
Serial Remember to set the line parameters for the serial interface

Calibration

"offset" is the calibration value to calculate the dB from the DC voltage steps:

  1. calibrate the unit on the front panel with "set DB"

  2. calibrate the sat-nms device driver by changing offset parameter. until the signal level displayed by the M&C system and the frontpanel matchs. Scale is 2 for all known models

LO Frequency

The conversion (LO) frequency is handled by the drivers and not by the Novella Receiver. Common values for this frequency are 10000 MHz or 11300 MHz for consumer. Ku-Band antennas. Set this value to zero if you intend to set the receive frequency in terms of L-band frequency.. If the LO is above above the receive frequency (e.g. for a C-Band. application) enter the LO frequency as a negative value

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.powerHex INTEGER R/O IntegerRange R/O (0 .. 0)
info.powerDC FLOAT R/O DoubleRange R/O (0.000 .. 0.000)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.controlMode CHOICE SETUP EnumRange (LOCAL REMOTE)
config.scale FLOAT SAVE SETUP DoubleRange (0.00 .. 0.00)
config.offset FLOAT SAVE SETUP DoubleRange (0.00 .. 0.00)
config.LOFreq FLOAT SAVE SETUP DoubleRange (0.000 .. 0.000)
frequency FLOAT DoubleRange (0.000 .. 0.000)
power FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
internal.test FLOAT R/O DoubleRange R/O (0.000 .. 0.000)
internal.frequency FLOAT R/O DoubleRange R/O (0.000 .. 0.000)
faults.01 ALARM R/O AlarmFlagRange R/O (Summary)