9.512 Paradise-RCP2

This page describes the device driver and the device window for the Paradise RCP2 redundancy controller with serial interface Tested with a RCP2 unit which handles online one WG-Switch and no redundancy

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the unit

parameter description
address Address of the unit

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.deviceType TEXT R/O StringRange R/O
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
meas.current.1 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.2 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.current.3 INTEGER R/O IntegerRange R/O (0 .. 0)
meas.voltage.1 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.voltage.2 FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
protection CHOICE EnumRange (MANUAL AUTO)
priority CHOICE EnumRange (POL1 POL2)
position CHOICE EnumRange (3-STBY 1-STBY 2-STBY)
position.1 CHOICE EnumRange (A B)
position.2 CHOICE EnumRange (A B)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (Summary)
faults.03 ALARM R/O AlarmFlagRange R/O (Power supply 1)
faults.04 ALARM R/O AlarmFlagRange R/O (Power supply 2)
faults.05 ALARM R/O AlarmFlagRange R/O (Auxiliary)
faults.11 ALARM R/O AlarmFlagRange R/O (LNA/LNB1)
faults.12 ALARM R/O AlarmFlagRange R/O (LNA/LNB2)
faults.13 ALARM R/O AlarmFlagRange R/O (LNA/LNB3)