9.513 Paradise-SSPA-SNMP

This page describes the device driver and the device window for the Paradise C-Band indoor SSPA amplifier. It was tested in a 1+1 redundancy configuration.

Device window pages

The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .

Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the SSPA.

parameter description
address The device IP address and the SNMP community strings as set at the device's front panel.
powerDisplayMode Select if you want to see gain or attenuation
rfUnits Switch the display mode between dBm and W. This changes the front panel display and the messages of the remote control protocol, but the drivers display both at any time.
sysMode Allows to select the system configuration.
standbyMode Allows to select the standby mode in a redundant configuration.

Communication protocol / Interface type

This device driver requires the SNMP protocol. Please remember to configure the ip settings (Main Menu - 2.Com Setup) and enable SNMP at the front panel

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
info.serial TEXT R/O StringRange R/O
info.model TEXT R/O StringRange R/O
info.revision TEXT R/O StringRange R/O
info.deviceType TEXT R/O StringRange R/O
info.ioBoardRev TEXT R/O StringRange R/O
info.digitalCoreRev TEXT R/O StringRange R/O
info.s1Position TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
config.readBackDelay INTEGER SAVE SETUP IntegerRange (100 .. 10000)
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.rfUnits CHOICE SETUP EnumRange (dBm W)
config.sysMode CHOICE SETUP EnumRange (StandAlone 1:1 1:2)
config.standbyMode CHOICE SETUP EnumRange (HotStandby ColdStandby)
config.powerSupplies CHOICE SAVE SETUP EnumRange (1 2)
config.hasRefPwrSensor CHOICE SAVE SETUP EnumRange (YES NO)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 20.0)
tx.attn FLOAT DoubleRange (0.0 .. 20.0)
tx.measuredLevel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.fwdPwr INTEGER R/O IntegerRange R/O (0 .. 0)
meas.refPwr FLOAT R/O DoubleRange R/O (0.00 .. 0.00)
meas.current FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.ps1Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.ps2Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.booster1Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.booster2Voltage FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.temp FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
red.mode CHOICE EnumRange DIS (AUTO MANUAL)
red.switch CHOICE EnumRange DIS (STANDBY ONLINE)
internal.fwd FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.ref FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
internal.s1 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.on CHOICE R/O EnumRange R/O (OFF ON)
faults.01 ALARM R/O AlarmFlagRange R/O (Summary)
faults.02 ALARM R/O AlarmFlagRange R/O (Power supply)
faults.03 ALARM R/O AlarmFlagRange R/O (High temp)
faults.04 ALARM R/O AlarmFlagRange R/O (Low regulator voltage)
faults.05 ALARM R/O AlarmFlagRange R/O (Low DC current)
faults.06 ALARM R/O AlarmFlagRange R/O (Auxiliary)
faults.07 ALARM R/O AlarmFlagRange R/O (BUC)
faults.08 ALARM R/O AlarmFlagRange R/O (Module 1)
faults.09 ALARM R/O AlarmFlagRange R/O (Module 2)
faults.10 ALARM R/O AlarmFlagRange R/O (Module 3)
faults.11 ALARM R/O AlarmFlagRange R/O (Module 4)
faults.12 ALARM R/O AlarmFlagRange R/O (Cooling fan)
faults.13 ALARM R/O AlarmFlagRange R/O (Low forward RF)
faults.14 ALARM R/O AlarmFlagRange R/O (High reflected RF)
faults.15 ALARM R/O AlarmFlagRange R/O (Switch position 1)
faults.16 ALARM R/O AlarmFlagRange R/O (Switch position 2)
faults.26 ALARM R/O AlarmFlagRange R/O (Standby)