This page describes the device driver and the device window for the Paradise C-Band indoor SSPA amplifier. It was tested in a 1+1 redundancy configuration.
Device window pages
The following table shows which device window pages are available with this individual device type. Tool-bar functions not mentioned here are described at the general description of device windows .
--- The operational upconverter parameters
--- Meter readings
--- The faults page.
--- The device info page.
--- The maintenance page. The configuration parameters described below are set at this page.Configuration parameters
At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the SSPA.
| parameter | description |
|---|---|
| address | The device IP address and the SNMP community strings as set at the device's front panel. |
| powerDisplayMode | Select if you want to see gain or attenuation |
| rfUnits | Switch the display mode between dBm and W. This changes the front panel display and the messages of the remote control protocol, but the drivers display both at any time. |
| sysMode | Allows to select the system configuration. |
| standbyMode | Allows to select the standby mode in a redundant configuration. |
Communication protocol / Interface type
This device driver requires the SNMP protocol. Please remember to configure the ip settings (Main Menu - 2.Com Setup) and enable SNMP at the front panel
Variables defined by this device driver
| name | type | flags | range |
|---|---|---|---|
| info.driver | TEXT | R/O | StringRange R/O |
| lowLevel.cmd | TEXT | StringRange | |
| lowLevel.reply | TEXT | R/O | StringRange R/O |
| faults.99 | ALARM | R/O | AlarmFlagRange R/O (Communication) |
| faults.commstat | TEXT | R/O | StringRange R/O |
| info.type | TEXT | R/O | StringRange R/O |
| info.port | TEXT | R/O | StringRange R/O |
| info.frame | TEXT | R/O | StringRange R/O |
| info.serial | TEXT | R/O | StringRange R/O |
| info.model | TEXT | R/O | StringRange R/O |
| info.revision | TEXT | R/O | StringRange R/O |
| info.deviceType | TEXT | R/O | StringRange R/O |
| info.ioBoardRev | TEXT | R/O | StringRange R/O |
| info.digitalCoreRev | TEXT | R/O | StringRange R/O |
| info.s1Position | TEXT | R/O | StringRange R/O |
| info.signal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| config.readBackDelay | INTEGER | SAVE SETUP | IntegerRange (100 .. 10000) |
| config.powerDisplayMode | CHOICE | SAVE SETUP | EnumRange (GAIN ATTN) |
| config.rfUnits | CHOICE | SETUP | EnumRange (dBm W) |
| config.sysMode | CHOICE | SETUP | EnumRange (StandAlone 1:1 1:2) |
| config.standbyMode | CHOICE | SETUP | EnumRange (HotStandby ColdStandby) |
| config.powerSupplies | CHOICE | SAVE SETUP | EnumRange (1 2) |
| config.hasRefPwrSensor | CHOICE | SAVE SETUP | EnumRange (YES NO) |
| tx.on | CHOICE | EnumRange (OFF ON) | |
| tx.gain | FLOAT | DoubleRange (0.0 .. 20.0) | |
| tx.attn | FLOAT | DoubleRange (0.0 .. 20.0) | |
| tx.measuredLevel | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.fwdPwr | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| meas.refPwr | FLOAT | R/O | DoubleRange R/O (0.00 .. 0.00) |
| meas.current | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.ps1Voltage | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.ps2Voltage | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.booster1Voltage | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.booster2Voltage | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| meas.temp | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| red.mode | CHOICE | EnumRange DIS (AUTO MANUAL) | |
| red.switch | CHOICE | EnumRange DIS (STANDBY ONLINE) | |
| internal.fwd | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.ref | FLOAT | R/O | DoubleRange R/O (0.0 .. 0.0) |
| internal.s1 | INTEGER | R/O | IntegerRange R/O (0 .. 0) |
| internal.on | CHOICE | R/O | EnumRange R/O (OFF ON) |
| faults.01 | ALARM | R/O | AlarmFlagRange R/O (Summary) |
| faults.02 | ALARM | R/O | AlarmFlagRange R/O (Power supply) |
| faults.03 | ALARM | R/O | AlarmFlagRange R/O (High temp) |
| faults.04 | ALARM | R/O | AlarmFlagRange R/O (Low regulator voltage) |
| faults.05 | ALARM | R/O | AlarmFlagRange R/O (Low DC current) |
| faults.06 | ALARM | R/O | AlarmFlagRange R/O (Auxiliary) |
| faults.07 | ALARM | R/O | AlarmFlagRange R/O (BUC) |
| faults.08 | ALARM | R/O | AlarmFlagRange R/O (Module 1) |
| faults.09 | ALARM | R/O | AlarmFlagRange R/O (Module 2) |
| faults.10 | ALARM | R/O | AlarmFlagRange R/O (Module 3) |
| faults.11 | ALARM | R/O | AlarmFlagRange R/O (Module 4) |
| faults.12 | ALARM | R/O | AlarmFlagRange R/O (Cooling fan) |
| faults.13 | ALARM | R/O | AlarmFlagRange R/O (Low forward RF) |
| faults.14 | ALARM | R/O | AlarmFlagRange R/O (High reflected RF) |
| faults.15 | ALARM | R/O | AlarmFlagRange R/O (Switch position 1) |
| faults.16 | ALARM | R/O | AlarmFlagRange R/O (Switch position 2) |
| faults.26 | ALARM | R/O | AlarmFlagRange R/O (Standby) |