Configuration parameters

At the maintenance page of the device window there are a couple of configuration parameters which must be set to make the software talk to the upconverter.

parameter description
address The device address (decimal) as set at the device's front panel.
Serial Remember to set the line parameters for the serial interface
powerDisplayMode Defines the display of gain or attenuation in the parameter section.
extMuteInput Defines to disable or enable the input for Hardware Mute (RF-Inhibit).
extRef Defines the reference source.
autoSave Store current parameters automatically in the instrument startup configuration.
accessMode Full Control: Enables changes on all tx parameters. Blocked by RSCM: Disables changes on all tx parameters (readonly).

Remote Control

Default TCP Port= 50505

Variables defined by this device driver

name type flags range
info.driver TEXT R/O StringRange R/O
lowLevel.cmd TEXT StringRange
lowLevel.reply TEXT R/O StringRange R/O
faults.99 ALARM R/O AlarmFlagRange R/O (Communication)
faults.commstat TEXT R/O StringRange R/O
info.type TEXT R/O StringRange R/O
info.port TEXT R/O StringRange R/O
info.frame TEXT R/O StringRange R/O
config.powerDisplayMode CHOICE SAVE SETUP EnumRange (GAIN ATTN)
config.extMuteInput CHOICE SETUP EnumRange (ENABLED DISABLED)
config.extRef CHOICE SETUP EnumRange (INTERNAL EXTERNAL AUTO)
config.autoSave CHOICE SETUP EnumRange (OFF ON)
config.accessMode CHOICE SAVE SETUP EnumRange (FULL CONTROL BLOCKED BY RSCM)
config.band CHOICE SAVE SETUP EnumRange (NONE S C C1 X KU KU1 K KA1 KA)
config.deviceComment TEXT SAVE SETUP StringRange
info.serial TEXT R/O StringRange R/O
info.FrontBaseVersion TEXT R/O StringRange R/O
info.FrontDeviceVersion TEXT R/O StringRange R/O
info.InterfaceVersion TEXT R/O StringRange R/O
info.ReferenceVersion TEXT R/O StringRange R/O
info.SynthesizerVersion TEXT R/O StringRange R/O
info.signal.on CHOICE R/O EnumRange R/O (OFF ON)
tx.on CHOICE EnumRange (OFF ON)
tx.gain FLOAT DoubleRange (0.0 .. 30.0)
tx.attn FLOAT DoubleRange (0.0 .. 30.0)
rx.frequency FLOAT DoubleRange (0.0000 .. 0.0000)
meas.temperature FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
meas.extRef BOOLEAN R/O BooleanRange R/O (true false)
meas.extMute BOOLEAN R/O BooleanRange R/O (true false)
info.temp.frontpanel FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.temp.controller FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.temp.refBoard FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
info.temp.synthesizer FLOAT R/O DoubleRange R/O (0.0 .. 0.0)
reset TEXT StringRange
internal.sa0 INTEGER R/O IntegerRange R/O (0 .. 0)
internal.sa1 INTEGER R/O IntegerRange R/O (0 .. 0)
faults.01 ALARM R/O AlarmFlagRange R/O (Remote access)
faults.02 ALARM R/O AlarmFlagRange R/O (OCXO oven cold)
faults.03 ALARM R/O AlarmFlagRange R/O (Internal alarm)
faults.04 ALARM R/O AlarmFlagRange R/O (Reference PLL alarm)
faults.05 ALARM R/O AlarmFlagRange R/O (Amplifier alarm)
faults.06 ALARM R/O AlarmFlagRange R/O (MW output alarm)
faults.07 ALARM R/O AlarmFlagRange R/O (Synthesizer alarm)
faults.09 ALARM R/O AlarmFlagRange R/O (External mute)
faults.10 ALARM R/O AlarmFlagRange R/O (External mute input)
faults.11 ALARM R/O AlarmFlagRange R/O (EEPROM)
faults.12 ALARM R/O AlarmFlagRange R/O (Temperature high)
faults.13 ALARM R/O AlarmFlagRange R/O (Temperature low)
faults.25 ALARM R/O AlarmFlagRange R/O (External Ref)
faults.26 ALARM R/O AlarmFlagRange R/O (RX OFF)