4.6.12 Modbus LNA Power Supply Monitoring Setup Registers

LNA supply monitoring setup registers start at register 6201, each channel covers 20 registers for its setup data. This means that channel 2 starts at register 06221, channel 3 at 06241 and so on.

LNA supply monitoring parameter are only available if this feature is licensed. Without license, all channels remain disabled.

The register definitions for channel 1 are:

  Register    Purpose               Remarks
  
  06201       channel 1 enable      1 = show readings, check limits
  06202       channel 2 name        up to 29 characters + 
                                    0-termination in 15 registers
  06217       minimum voltage      unsigned integer value in steps
                                    of 0.01V
  06218       minimum current       unsigned integer value in steps
                                    of 0.1mA
  06219       maximum current       unsigned integer value in steps
                                    of 0.1mA