6 Specification

General Interfaces qty standard license up to (via license code) Connector No. remark
System Interfaces All interfaces (except the Ethernet-interface) have to be connected via Mini Combicon MCV1,5/XX-G-3,5
external Temperature measurement 4 17 via external PT1000 sensors, accuracy +/- 3°C, range: -40 to +60°C, alarm threshold, digital outputs can be assigned to setup up to 4 temperature controllers (heater or cooling) as an option
internal Temperature measurement 1 --- via internal on-chip-sensor, accuracy +/-3°C, Alarm threshold
internal clock/ calendar 1 --- Real-time clock/ calendar. If power supply is missing, a goldcap capacitor keeps the clock running for min. 7 days
LNA/LNB power supply monitoring 6 38, 39 Monitoring of current and voltage of each LNA/LNB. Alarms can be used to trigger a redundancy switchover. External Power supply 15…24VDC needed. Max. 600mA per LNA/LNB
digital input 16 48 6, 7, 8, 9, 18, 19, 20, 21, 26, 27, 32, 33 via optocoupler, indication current: ~3mA @ 24V DC
digital output 6 16 relay contacts, max. continuous current: 1A, max continuous voltage: 48V DC
HPA-muting/ digital output 10 4, 5 Photomos-relays, per relay max. continuous current: 130mA, max. continuous voltage: 48V, on-state-resistance typ. 18Ohm, max. 25Ohm
HPA-muting/ RF-inhibit matrix 10x16 software HPA-muting or DIP-switches for hardware-HPA-muting
waveguide-switching 4 16 10, 11, 12, 13, 22, 23, 24, 25, 28, 29, 30, 31, 34, 35, 36, 37 maximum peak switching current: 5A
waveguide-indication 4 16 see above. via optocoupler, indication current: ~3mA @ 24V DC
weveguide inhibit-indication 16 see above. indication current ~5mA @ 24V DC
Redundancy switching 1:1, up to 16 --- 1:1 and 2:1 can be used at the same time in any combination. Maximum quantity is limited by quantity of enabled waveguide Switch Interfaces!
Redundancy switching 2:1, up to 8 --- 1:1 and 2:1 can be used at the same time in any combination. Maximum quantity is limited by quantity of enabled waveguide Switch Interfaces!
NTP time server interface 2 --- Interface for master and redundant NTP server
power output 3 14, 38, 39 24V DC, max 500mA (CON14), max 300mA (CON38, 39)
Ethernet 1 1 RJ45, 10/100-Base-T, for controlling the sat-nms IO-FEP2 via HTTP GET, SNMP, Modbus or any Web-browser
RS232 1 15 for remote controlling the sat-nms IO-FEP2
I²C 15 for special requirements, only usable with customized Software, inactive by default
M&C Interface Specification description
interface for M&C and user 10/ 100-Base-T, Via HTTP GET requests, RS232, SNMP, Modbus
Electrical and Mechanical Specification, Environmental conditions Connector No. description
Supply Voltage 2 (main), 3 (backup) 24 V DC, +5%/-10%
Power consumption 24V INT 2, 3 max. 100mA
Power consumption 24V EXT 2, 3 max. 750mA (excluding power output at CON14/38/39 and switching current of waveguide switches)
LNA/LNB supply voltage 38, 39 15...24V DC, max. 600mA per LNA/LNB
Temperature range 5° to 40° C
Humidity up to 90% non condensing
DIN rail module 307 x 139 x 60 mm
Weight 1.3 kg